{"id":8356,"date":"2026-11-23T04:05:56","date_gmt":"2026-11-23T04:05:56","guid":{"rendered":"https:\/\/www.grandye-switch.com\/micro-switch-wiring\/"},"modified":"2026-11-23T04:05:56","modified_gmt":"2026-11-23T04:05:56","slug":"micro-switch-wiring","status":"publish","type":"page","link":"https:\/\/www.grandye-switch.com\/fa\/micro-switch-wiring\/","title":{"rendered":"Micro Switch Wiring: Diagrams, COM\/NO\/NC &#038; 3-Wire Connections"},"content":{"rendered":"<link rel=\"stylesheet\" href=\"https:\/\/www.grandye-switch.com\/wp-content\/uploads\/2026\/11\/zg-topic.css\">\n<div class=\"zg-topic\">\n<section class=\"zg-hero\">\n<div class=\"zg-wrap\">\n<p class=\"zg-breadcrumb\"><a href=\"https:\/\/www.grandye-switch.com\/\">Home<\/a> \/ <a href=\"https:\/\/www.grandye-switch.com\/micro-switch\/\">Micro Switch<\/a> \/ Wiring Guide<\/p>\n<p>    <span class=\"zg-kicker\">Wiring & Testing<\/span><\/p>\n<h1>Micro Switch Wiring: Diagrams, COM\/NO\/NC & 3-Wire Connections<\/h1>\n<p class=\"zg-lead\">Learn how to identify COM, NO and NC terminals, wire a two-wire or three-wire micro switch, test it with a multimeter, and avoid the mistakes that cause unreliable switching.<\/p>\n<div class=\"zg-actions\">\n      <a class=\"zg-btn\" href=\"#terminals\">Start with terminals<\/a><br \/>\n      <a class=\"zg-btn zg-btn-light\" href=\"https:\/\/www.grandye-switch.com\/contact-us\/\">Ask an engineer<\/a>\n    <\/div>\n<\/p><\/div>\n<\/section>\n<div class=\"zg-wrap\">\n<section class=\"zg-section\" id=\"safety\">\n<h2>Safety first<\/h2>\n<div class=\"zg-warning\"><strong>Before wiring:<\/strong> disconnect power and verify that the circuit is dead. Mains voltage can cause serious injury or death. If you are not qualified to work on mains wiring, use a licensed electrician. The diagrams below explain switching logic; they are not a substitute for local electrical codes and the switch datasheet.<\/div>\n<p>Most low-voltage micro switches are used as <strong>signal switches<\/strong>, not as the main power switch for a motor or heater. Check the contact rating for the actual voltage, current and load type. A switch rated for a small signal current should not be used directly to switch a large inductive load.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"terminals\">\n<h2>Identify the terminals: COM, NO and NC<\/h2>\n<p>A three-terminal micro switch is usually an SPDT changeover switch:<\/p>\n<table class=\"zg-table\">\n<thead>\n<tr>\n<th>Terminal<\/th>\n<th>Meaning<\/th>\n<th>State at rest<\/th>\n<th>State when actuated<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>COM<\/strong><\/td>\n<td>Common terminal<\/td>\n<td>Connected to NC<\/td>\n<td>Connected to NO<\/td>\n<\/tr>\n<tr>\n<td><strong>NO<\/strong><\/td>\n<td>Normally open<\/td>\n<td>Open circuit<\/td>\n<td>Closed to COM<\/td>\n<\/tr>\n<tr>\n<td><strong>NC<\/strong><\/td>\n<td>Normally closed<\/td>\n<td>Closed to COM<\/td>\n<td>Open circuit<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Do not assume that a three-wire switch has \u201cpositive, negative and signal\u201d wires. Unless the product is a powered sensor, the three terminals are normally COM, NO and NC. Always confirm the terminal markings and datasheet before applying power.<\/p>\n<p>A two-terminal switch is usually SPST-NO or SPST-NC. It has no changeover contact, so it can only open or close one circuit.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"two-wire\">\n<h2>Two-wire micro switch wiring diagram<\/h2>\n<p>A two-wire switch is placed in series with the load. When the switch closes, current flows through the load; when it opens, the load turns off.<\/p>\n<div class=\"zg-diagram\">\n      <svg viewBox=\"0 0 820 250\" role=\"img\" aria-labelledby=\"wire2-title\">\n        <title id=\"wire2-title\">Two-wire micro switch in series with a power source and load<\/title>\n        <rect x=\"25\" y=\"85\" width=\"140\" height=\"80\" rx=\"10\" fill=\"#0b2745\"\/>\n        <text x=\"95\" y=\"118\" text-anchor=\"middle\" fill=\"#fff\" font-size=\"16\" font-family=\"Arial\">Power<\/text>\n        <text x=\"95\" y=\"140\" text-anchor=\"middle\" fill=\"#cfe3ff\" font-size=\"13\" font-family=\"Arial\">source<\/text>\n        <line x1=\"165\" y1=\"125\" x2=\"305\" y2=\"125\" stroke=\"#0b63ce\" stroke-width=\"4\"\/>\n        <rect x=\"305\" y=\"85\" width=\"180\" height=\"80\" rx=\"10\" fill=\"#eaf3ff\" stroke=\"#0b63ce\" stroke-width=\"2\"\/>\n        <text x=\"395\" y=\"118\" text-anchor=\"middle\" fill=\"#0b2745\" font-size=\"16\" font-family=\"Arial\">Micro switch<\/text>\n        <text x=\"395\" y=\"140\" text-anchor=\"middle\" fill=\"#33475b\" font-size=\"13\" font-family=\"Arial\">SPST, in series<\/text>\n        <line x1=\"485\" y1=\"125\" x2=\"625\" y2=\"125\" stroke=\"#0b63ce\" stroke-width=\"4\"\/>\n        <rect x=\"625\" y=\"85\" width=\"160\" height=\"80\" rx=\"10\" fill=\"#0b2745\"\/>\n        <text x=\"705\" y=\"118\" text-anchor=\"middle\" fill=\"#fff\" font-size=\"16\" font-family=\"Arial\">Load<\/text>\n        <text x=\"705\" y=\"140\" text-anchor=\"middle\" fill=\"#cfe3ff\" font-size=\"13\" font-family=\"Arial\">lamp, relay, etc.<\/text>\n        <line x1=\"705\" y1=\"165\" x2=\"705\" y2=\"215\" stroke=\"#0b63ce\" stroke-width=\"4\"\/>\n        <line x1=\"705\" y1=\"215\" x2=\"95\" y2=\"215\" stroke=\"#0b63ce\" stroke-width=\"4\"\/>\n        <line x1=\"95\" y1=\"215\" x2=\"95\" y2=\"165\" stroke=\"#0b63ce\" stroke-width=\"4\"\/>\n      <\/svg><\/p>\n<p class=\"zg-small\">Series connection: power \u2192 switch \u2192 load \u2192 return. The switch carries the load current, so its rating must cover that load.<\/p>\n<\/p><\/div>\n<p>Use a two-wire NO switch when you want the load to turn on only while the actuator is pressed. Use a two-wire NC switch when the load should remain on and turn off when the actuator is pressed, or when an open circuit should indicate a fault.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"three-wire\">\n<h2>Three-wire micro switch wiring<\/h2>\n<p>A three-terminal SPDT micro switch lets you choose the contact that is connected to COM. The three wires are not a power supply, ground and signal; they are the common contact and the two selectable contacts.<\/p>\n<div class=\"zg-diagram\">\n      <svg viewBox=\"0 0 820 300\" role=\"img\" aria-labelledby=\"wire3-title\">\n        <title id=\"wire3-title\">Three-wire SPDT micro switch with COM, NO and NC terminals<\/title>\n        <rect x=\"40\" y=\"60\" width=\"190\" height=\"180\" rx=\"12\" fill=\"#0b2745\"\/>\n        <text x=\"135\" y=\"98\" text-anchor=\"middle\" fill=\"#fff\" font-size=\"16\" font-family=\"Arial\">SPDT switch<\/text>\n        <circle cx=\"105\" cy=\"140\" r=\"7\" fill=\"#fff\"\/><text x=\"120\" y=\"145\" fill=\"#fff\" font-size=\"14\" font-family=\"Arial\">COM<\/text>\n        <circle cx=\"105\" cy=\"180\" r=\"7\" fill=\"#fff\"\/><text x=\"120\" y=\"185\" fill=\"#fff\" font-size=\"14\" font-family=\"Arial\">NO<\/text>\n        <circle cx=\"105\" cy=\"220\" r=\"7\" fill=\"#fff\"\/><text x=\"120\" y=\"225\" fill=\"#fff\" font-size=\"14\" font-family=\"Arial\">NC<\/text>\n        <path d=\"M230 140 C330 140 330 110 430 110\" fill=\"none\" stroke=\"#0b63ce\" stroke-width=\"4\"\/>\n        <path d=\"M230 180 C330 180 330 170 430 170\" fill=\"none\" stroke=\"#f59e0b\" stroke-width=\"4\"\/>\n        <path d=\"M230 220 C330 220 330 230 430 230\" fill=\"none\" stroke=\"#7c8da0\" stroke-width=\"4\"\/>\n        <rect x=\"430\" y=\"82\" width=\"250\" height=\"56\" rx=\"9\" fill=\"#eaf3ff\" stroke=\"#0b63ce\"\/>\n        <text x=\"555\" y=\"116\" text-anchor=\"middle\" fill=\"#0b2745\" font-size=\"15\" font-family=\"Arial\">Controller input<\/text>\n        <rect x=\"430\" y=\"142\" width=\"250\" height=\"56\" rx=\"9\" fill=\"#eaf3ff\" stroke=\"#f59e0b\"\/>\n        <text x=\"555\" y=\"176\" text-anchor=\"middle\" fill=\"#0b2745\" font-size=\"15\" font-family=\"Arial\">Alternate signal \/ circuit<\/text>\n        <rect x=\"430\" y=\"202\" width=\"250\" height=\"56\" rx=\"9\" fill=\"#eaf3ff\" stroke=\"#7c8da0\"\/>\n        <text x=\"555\" y=\"236\" text-anchor=\"middle\" fill=\"#0b2745\" font-size=\"15\" font-family=\"Arial\">Second circuit \/ NC path<\/text>\n      <\/svg><\/p>\n<p class=\"zg-small\">SPDT changeover: COM connects to NC at rest and to NO when the actuator is pressed.<\/p>\n<\/p><\/div>\n<p>For a microcontroller or PLC input, connect COM to the signal common (or ground, depending on the input design), NO to the input, and configure a pull-up or pull-down resistor as required. The switch is a dry contact; it does not generate a voltage by itself.<\/p>\n<p>If the controller input expects a closed circuit for normal operation, use the NC contact so a broken wire or a pressed switch produces a detectable change. This is common in safety and door-monitoring circuits.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"steps\">\n<h2>How to wire a micro switch: step by step<\/h2>\n<ol>\n<li><strong>Disconnect and lock out power.<\/strong> Confirm zero voltage with a tester before touching conductors.<\/li>\n<li><strong>Read the switch markings.<\/strong> Identify COM, NO and NC. If the markings are missing, use a multimeter continuity test to map the terminals.<\/li>\n<li><strong>Choose the contact logic.<\/strong> Use NO for \u201cclose on actuation\u201d and NC for \u201copen on actuation\u201d or fail-safe monitoring.<\/li>\n<li><strong>Prepare the wire.<\/strong> Strip the correct length, use the specified terminal type and avoid nicking the conductor.<\/li>\n<li><strong>Connect COM first.<\/strong> Then connect the selected contact. For low-voltage signals, keep wires short and route them away from power cables.<\/li>\n<li><strong>Provide strain relief.<\/strong> Secure the cable so movement is not transferred to the terminals or solder joints.<\/li>\n<li><strong>Test before connecting the load.<\/strong> Use continuity mode and operate the actuator to confirm the expected open\/closed states.<\/li>\n<li><strong>Insulate and reassemble.<\/strong> Check clearance, replace covers and test the complete assembly under normal operating conditions.<\/li>\n<\/ol>\n<\/section>\n<section class=\"zg-section\" id=\"testing\">\n<h2>How to test a micro switch with a multimeter<\/h2>\n<table class=\"zg-table\">\n<thead>\n<tr>\n<th>Test<\/th>\n<th>Meter setting<\/th>\n<th>Expected result<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>COM to NC, at rest<\/td>\n<td>Continuity \/ resistance<\/td>\n<td>Continuity (near 0 \u03a9)<\/td>\n<\/tr>\n<tr>\n<td>COM to NO, at rest<\/td>\n<td>Continuity \/ resistance<\/td>\n<td>Open circuit<\/td>\n<\/tr>\n<tr>\n<td>COM to NC, actuated<\/td>\n<td>Continuity \/ resistance<\/td>\n<td>Open circuit<\/td>\n<\/tr>\n<tr>\n<td>COM to NO, actuated<\/td>\n<td>Continuity \/ resistance<\/td>\n<td>Continuity (near 0 \u03a9)<\/td>\n<\/tr>\n<tr>\n<td>Contact resistance<\/td>\n<td>Low-ohm meter<\/td>\n<td>Compare with datasheet; a rising value may indicate worn contacts<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>For a two-terminal switch, test across the two terminals: an NO switch reads open at rest and closed when actuated; an NC switch does the opposite.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"mistakes\">\n<h2>Common micro switch wiring mistakes<\/h2>\n<div class=\"zg-grid\">\n<div class=\"zg-card\">\n<h3>Confusing NO and NC<\/h3>\n<p>The circuit works in reverse, or a safety circuit remains closed when it should open. Confirm the terminal map before power-up.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Using an AC rating for DC<\/h3>\n<p>DC arcs are harder to extinguish. A switch rated for AC may fail early on the same DC load.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Switching too much current<\/h3>\n<p>Use a relay or contactor for high-current loads; the micro switch should control the relay coil, not the main load.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>No strain relief<\/h3>\n<p>Movement and vibration can crack solder joints or loosen terminals.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Excess soldering heat<\/h3>\n<p>Too much heat can deform the housing or change the spring characteristics. Follow the soldering profile.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Ignoring contact bounce<\/h3>\n<p>Digital inputs may need hardware or software debounce, especially for mouse buttons and encoders.<\/p>\n<\/div><\/div>\n<\/section>\n<section class=\"zg-section\" id=\"faq\">\n<h2>Micro switch wiring FAQ<\/h2>\n<div class=\"zg-faq\">\n<details>\n<summary>How do I know which terminal is COM?<\/summary>\n<p>Look for the COM marking or consult the datasheet. If markings are absent, use a multimeter: COM is the terminal that changes continuity to the other two terminals when the actuator is operated.<\/p>\n<\/details>\n<details>\n<summary>Can I connect a micro switch directly to an Arduino or PLC?<\/summary>\n<p>Yes, as a dry contact input, provided the input circuit uses a suitable pull-up or pull-down and the switch is rated for the signal voltage and current. Use debounce in software if the input is sensitive.<\/p>\n<\/details>\n<details>\n<summary>What is a 3-wire micro switch used for?<\/summary>\n<p>It provides a changeover contact: COM can connect to NO or NC. This is useful for selecting between two circuits, reversing logic, or providing both open and closed signals.<\/p>\n<\/details>\n<details>\n<summary>Should I use NO or NC for a safety switch?<\/summary>\n<p>Safety circuits often use NC contacts so that a broken wire or a pressed switch opens the circuit. The correct choice depends on the risk assessment and controller design.<\/p>\n<\/details>\n<details>\n<summary>Can a micro switch be wired in either direction?<\/summary>\n<p>A dry contact is not polarised in the same way as a diode, but the load circuit and contact ratings still matter. Follow the datasheet and local wiring codes.<\/p>\n<\/details>\n<details>\n<summary>Why does my switch show continuity in both positions?<\/summary>\n<p>The meter may be on the wrong range, the wires may be shorted, or the switch may have welded contacts. Disconnect the switch and test it alone.<\/p>\n<\/details><\/div>\n<\/section>\n<div class=\"zg-cta\">\n<div>\n<h2>Need a switch with the right terminals?<\/h2>\n<p>ZING EAR offers PCB, solder, quick-connect and wire-harness terminals across the G5, G6, G10 and G3 series. Send your wiring requirements for a sample.<\/p>\n<\/div>\n<p>    <a class=\"zg-btn zg-btn-light\" href=\"https:\/\/www.grandye-switch.com\/contact-us\/\">Request a sample<\/a>\n  <\/div>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"How do I know which terminal is COM?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Look for the COM marking or consult the datasheet. If markings are absent, use a multimeter: COM is the terminal that changes continuity to the other two terminals when the actuator is operated.\"}},\n{\"@type\":\"Question\",\"name\":\"Can I connect a micro switch directly to an Arduino or PLC?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, as a dry contact input, provided the input circuit uses a suitable pull-up or pull-down and the switch is rated for the signal voltage and current. Use debounce in software if the input is sensitive.\"}},\n{\"@type\":\"Question\",\"name\":\"What is a 3-wire micro switch used for?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It provides a changeover contact: COM can connect to NO or NC. This is useful for selecting between two circuits, reversing logic, or providing both open and closed signals.\"}},\n{\"@type\":\"Question\",\"name\":\"Should I use NO or NC for a safety switch?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Safety circuits often use NC contacts so that a broken wire or a pressed switch opens the circuit. The correct choice depends on the risk assessment and controller design.\"}},\n{\"@type\":\"Question\",\"name\":\"Why does my switch show continuity in both positions?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The meter may be on the wrong range, the wires may be shorted, or the switch may have welded contacts. Disconnect the switch and test it alone.\"}}\n]}\n<\/script><br \/>\n\n","protected":false},"excerpt":{"rendered":"<p>Micro switch wiring guide with COM, NO and NC diagrams, 2-wire and 3-wire connections, multimeter testing and common wiring mistakes.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"footnotes":""},"class_list":["post-8356","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/pages\/8356","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/comments?post=8356"}],"version-history":[{"count":0,"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/pages\/8356\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.grandye-switch.com\/fa\/wp-json\/wp\/v2\/media?parent=8356"}],"curies":[{"name":"\u0648\u0631\u062f\u067e\u0631\u0633","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}