{"id":8383,"date":"2026-11-24T05:45:18","date_gmt":"2026-11-24T05:45:18","guid":{"rendered":"https:\/\/www.grandye-switch.com\/dpdt-limit-switch\/"},"modified":"2026-11-24T05:45:18","modified_gmt":"2026-11-24T05:45:18","slug":"dpdt-limit-switch","status":"publish","type":"page","link":"https:\/\/www.grandye-switch.com\/ja\/dpdt-limit-switch\/","title":{"rendered":"DPDT Limit Switch: Contacts, Wiring &#038; Selection Guide"},"content":{"rendered":"<link rel=\"stylesheet\" href=\"https:\/\/www.grandye-switch.com\/wp-content\/uploads\/2026\/11\/zg-topic.css\">\n<div class=\"zg-topic\">\n<section class=\"zg-hero\">\n<div class=\"zg-wrap\">\n<p class=\"zg-breadcrumb\"><a href=\"https:\/\/www.grandye-switch.com\/\">Home<\/a> \/ <a href=\"https:\/\/www.grandye-switch.com\/limit-switch\/\">Limit Switch<\/a> \/ DPDT Limit Switch<\/p>\n<p>    <span class=\"zg-kicker\">Changeover Control<\/span><\/p>\n<h1>DPDT Limit Switch: Contacts, Wiring & Selection Guide<\/h1>\n<p class=\"zg-lead\">A DPDT limit switch contains two independent changeover circuits operated by one actuator. This guide explains the contacts, wiring options, applications and how to choose a DPDT micro limit switch.<\/p>\n<div class=\"zg-actions\">\n      <a class=\"zg-btn\" href=\"#wiring\">See wiring<\/a><br \/>\n      <a class=\"zg-btn zg-btn-light\" href=\"https:\/\/www.grandye-switch.com\/product\/dpdt-micro-limit-switch\/\">View DPDT switch<\/a>\n    <\/div>\n<\/p><\/div>\n<\/section>\n<div class=\"zg-wrap\">\n<section class=\"zg-section\">\n<h2>What is a DPDT limit switch?<\/h2>\n<div class=\"zg-answer\">\n<p><strong>DPDT means double-pole, double-throw.<\/strong> The switch has two independent poles, and each pole has a common contact that changes between a normally closed (NC) and normally open (NO) contact. One actuator operates both poles at the same time.<\/p>\n<\/div>\n<p>A DPDT limit switch is useful when one mechanical position must change two separate circuits, reverse a motor, select between two signals, or provide a redundant contact set. It is different from an SPDT switch, which has only one changeover circuit.<\/p>\n<\/section>\n<section class=\"zg-section\">\n<h2>DPDT contact map<\/h2>\n<table class=\"zg-table\">\n<thead>\n<tr>\n<th>Terminal group<\/th>\n<th>At rest<\/th>\n<th>When actuated<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>COM 1 \u2192 NC 1<\/td>\n<td>Closed<\/td>\n<td>Open<\/td>\n<\/tr>\n<tr>\n<td>COM 1 \u2192 NO 1<\/td>\n<td>Open<\/td>\n<td>Closed<\/td>\n<\/tr>\n<tr>\n<td>COM 2 \u2192 NC 2<\/td>\n<td>Closed<\/td>\n<td>Open<\/td>\n<\/tr>\n<tr>\n<td>COM 2 \u2192 NO 2<\/td>\n<td>Open<\/td>\n<td>Closed<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Terminal markings vary by manufacturer. Always identify the two common terminals and their corresponding NO\/NC contacts from the datasheet before wiring. Do not assume that the terminals are arranged in a particular order.<\/p>\n<\/section>\n<section class=\"zg-section\">\n<h2>DPDT vs SPDT<\/h2>\n<div class=\"zg-grid\">\n<div class=\"zg-card\">\n<h3>SPDT<\/h3>\n<p>One common contact changes between one NO and one NC contact. Three terminals are typical. Good for a single changeover signal.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>DPDT<\/h3>\n<p>Two independent changeover circuits. Six terminals are typical. Good for reversing, dual signals or isolated circuits.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>DPST<\/h3>\n<p>Two independent on\/off contacts, without changeover. Four terminals are typical.<\/p>\n<\/div><\/div>\n<p>For contact-state basics, see <a href=\"https:\/\/www.grandye-switch.com\/normally-open-vs-normally-closed-micro-switch\/\">NO vs NC micro switches<\/a>.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"wiring\">\n<h2>DPDT limit switch wiring<\/h2>\n<p>A common use is motor reversing. The two poles can swap the polarity or phase connections while the other contacts provide a signal or interlock. The exact wiring depends on the motor, controller and safety requirements.<\/p>\n<ol>\n<li>Identify both common terminals and their NO\/NC contacts.<\/li>\n<li>Draw the circuit in the rest and actuated states before connecting power.<\/li>\n<li>Confirm that the switch rating covers the motor or load, including inrush current.<\/li>\n<li>Use a relay or contactor if the motor current exceeds the switch rating.<\/li>\n<li>Provide strain relief and protect terminals from accidental contact.<\/li>\n<li>Test the circuit with the actuator in both positions and verify the expected state change.<\/li>\n<\/ol>\n<div class=\"zg-warning\"><strong>Motor reversing and line-voltage wiring can be dangerous.<\/strong> Use a qualified electrician and follow the motor controller\u2019s wiring diagram. A micro switch should not be used beyond its published rating.<\/div>\n<p>For terminal testing and COM\/NO\/NC identification, see the <a href=\"https:\/\/www.grandye-switch.com\/micro-switch-wiring\/\">micro switch wiring guide<\/a>.<\/p>\n<\/section>\n<section class=\"zg-section\">\n<h2>Typical applications<\/h2>\n<div class=\"zg-grid\">\n<div class=\"zg-card\">\n<h3>Motor reversing<\/h3>\n<p>Change the polarity or control direction at a mechanical end position.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Two-circuit signalling<\/h3>\n<p>Send a position signal to two controllers or provide a redundant contact.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Polarity selection<\/h3>\n<p>Switch a DC circuit between two paths at a defined position.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Safety and monitoring<\/h3>\n<p>Use one pole for control and the other for a monitoring input, subject to the safety design.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Industrial limits<\/h3>\n<p>Detect end travel while changing a secondary circuit.<\/p>\n<\/div>\n<div class=\"zg-card\">\n<h3>Equipment interlocks<\/h3>\n<p>Change two circuits when a guard, door or lever reaches a position.<\/p>\n<\/div><\/div>\n<\/section>\n<section class=\"zg-section\">\n<h2>How to choose a DPDT limit switch<\/h2>\n<ul>\n<li><strong>Contact form:<\/strong> confirm DPDT and the terminal arrangement.<\/li>\n<li><strong>Rating:<\/strong> voltage, current, AC\/DC and load type; check inrush.<\/li>\n<li><strong>Actuator:<\/strong> plunger, lever, roller or custom; match the cam and travel.<\/li>\n<li><strong>Mounting:<\/strong> body size, holes and adjustment range.<\/li>\n<li><strong>Terminals:<\/strong> screw, quick-connect, PCB or wire harness.<\/li>\n<li><strong>Environment:<\/strong> IP rating, temperature and contamination.<\/li>\n<li><strong>Life and approvals:<\/strong> mechanical\/electrical cycles and required certifications.<\/li>\n<\/ul>\n<p>ZING EAR offers a <a href=\"https:\/\/www.grandye-switch.com\/product\/dpdt-micro-limit-switch\/\">DPDT micro limit switch<\/a> positioned as an alternative to the Crouzet 83133169, plus the <a href=\"https:\/\/www.grandye-switch.com\/product\/dpdt-momentary-micro-switch\/\">DPDT momentary micro switch<\/a> and <a href=\"https:\/\/www.grandye-switch.com\/g21-dpdt-limit-micro-switch\/\">G21 DPDT limit switch<\/a>.<\/p>\n<\/section>\n<section class=\"zg-section\">\n<h2>Related limit switch guides<\/h2>\n<p>For position accuracy and repeatability, read the <a href=\"https:\/\/www.grandye-switch.com\/precision-limit-switch\/\">precision limit switch guide<\/a>. For the full range, see the <a href=\"https:\/\/www.grandye-switch.com\/limit-switch\/\">limit switch overview<\/a> and <a href=\"https:\/\/www.grandye-switch.com\/types-of-micro-switches\/\">types of micro switches<\/a>.<\/p>\n<\/section>\n<section class=\"zg-section\" id=\"faq\">\n<h2>DPDT limit switch FAQ<\/h2>\n<div class=\"zg-faq\">\n<details>\n<summary>What does DPDT mean on a limit switch?<\/summary>\n<p>Double-pole, double-throw: two independent changeover circuits operated by one actuator. Each pole has a common contact, a normally open contact and a normally closed contact.<\/p>\n<\/details>\n<details>\n<summary>How many terminals does a DPDT switch have?<\/summary>\n<p>A typical DPDT switch has six terminals: two commons and four selectable contacts. The exact layout depends on the manufacturer.<\/p>\n<\/details>\n<details>\n<summary>Can a DPDT switch reverse a motor?<\/summary>\n<p>It can change polarity or control paths, but the switch rating and motor circuit must be designed correctly. For larger motors, use a relay or contactor and follow the controller diagram.<\/p>\n<\/details>\n<details>\n<summary>What is the difference between DPDT and SPDT?<\/summary>\n<p>SPDT has one changeover circuit; DPDT has two independent changeover circuits operated together.<\/p>\n<\/details>\n<details>\n<summary>How do I identify the common terminals?<\/summary>\n<p>Use the datasheet and a multimeter. The common terminal changes continuity from NC to NO when the actuator is operated.<\/p>\n<\/details>\n<details>\n<summary>Can ZING EAR customize a DPDT limit switch?<\/summary>\n<p>ZING EAR can review custom actuators, terminals, wiring and ratings for OEM projects.<\/p>\n<\/details><\/div>\n<\/section>\n<div class=\"zg-cta\">\n<div>\n<h2>Need a DPDT limit switch?<\/h2>\n<p>Send your circuit diagram, load, actuator and mounting requirements. ZING EAR can recommend a standard or custom DPDT switch.<\/p>\n<\/div>\n<p>    <a class=\"zg-btn zg-btn-light\" href=\"https:\/\/www.grandye-switch.com\/contact-us\/\">Request a sample<\/a>\n  <\/div>\n<\/div>\n<\/div>\n<p><script type=\"application\/ld+json\">\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[\n{\"@type\":\"Question\",\"name\":\"What does DPDT mean on a limit switch?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Double-pole, double-throw: two independent changeover circuits operated by one actuator. Each pole has a common contact, a normally open contact and a normally closed contact.\"}},\n{\"@type\":\"Question\",\"name\":\"How many terminals does a DPDT switch have?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A typical DPDT switch has six terminals: two commons and four selectable contacts. The exact layout depends on the manufacturer.\"}},\n{\"@type\":\"Question\",\"name\":\"Can a DPDT switch reverse a motor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It can change polarity or control paths, but the switch rating and motor circuit must be designed correctly. For larger motors, use a relay or contactor and follow the controller diagram.\"}},\n{\"@type\":\"Question\",\"name\":\"What is the difference between DPDT and SPDT?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SPDT has one changeover circuit; DPDT has two independent changeover circuits operated together.\"}},\n{\"@type\":\"Question\",\"name\":\"How do I identify the common terminals?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Use the datasheet and a multimeter. The common terminal changes continuity from NC to NO when the actuator is operated.\"}},\n{\"@type\":\"Question\",\"name\":\"Can ZING EAR customize a DPDT limit switch?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"ZING EAR can review custom actuators, terminals, wiring and ratings for OEM projects.\"}}\n]}\n<\/script><br \/>\n\n","protected":false},"excerpt":{"rendered":"<p>DPDT limit switch contacts, terminal map, motor reversing and wiring considerations, plus selection and product options.<\/p>","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"footnotes":""},"class_list":["post-8383","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/pages\/8383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/comments?post=8383"}],"version-history":[{"count":0,"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/pages\/8383\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.grandye-switch.com\/ja\/wp-json\/wp\/v2\/media?parent=8383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}