Changeover Control
DPDT Limit Switch: Contacts, Wiring & Selection Guide
A DPDT limit switch contains two independent changeover circuits operated by one actuator. This guide explains the contacts, wiring options, applications and how to choose a DPDT micro limit switch.
What is a DPDT limit switch?
DPDT means double-pole, double-throw. The switch has two independent poles, and each pole has a common contact that changes between a normally closed (NC) and normally open (NO) contact. One actuator operates both poles at the same time.
A DPDT limit switch is useful when one mechanical position must change two separate circuits, reverse a motor, select between two signals, or provide a redundant contact set. It is different from an SPDT switch, which has only one changeover circuit.
DPDT contact map
| Terminal group | At rest | When actuated |
|---|---|---|
| COM 1 → NC 1 | Closed | Open |
| COM 1 → NO 1 | Open | Closed |
| COM 2 → NC 2 | Closed | Open |
| COM 2 → NO 2 | Open | Closed |
Terminal markings vary by manufacturer. Always identify the two common terminals and their corresponding NO/NC contacts from the datasheet before wiring. Do not assume that the terminals are arranged in a particular order.
DPDT vs SPDT
SPDT
One common contact changes between one NO and one NC contact. Three terminals are typical. Good for a single changeover signal.
دی پی دی تی
Two independent changeover circuits. Six terminals are typical. Good for reversing, dual signals or isolated circuits.
DPST
Two independent on/off contacts, without changeover. Four terminals are typical.
For contact-state basics, see NO vs NC micro switches.
DPDT limit switch wiring
A common use is motor reversing. The two poles can swap the polarity or phase connections while the other contacts provide a signal or interlock. The exact wiring depends on the motor, controller and safety requirements.
- Identify both common terminals and their NO/NC contacts.
- Draw the circuit in the rest and actuated states before connecting power.
- Confirm that the switch rating covers the motor or load, including inrush current.
- Use a relay or contactor if the motor current exceeds the switch rating.
- Provide strain relief and protect terminals from accidental contact.
- Test the circuit with the actuator in both positions and verify the expected state change.
For terminal testing and COM/NO/NC identification, see the micro switch wiring guide.
Typical applications
Motor reversing
Change the polarity or control direction at a mechanical end position.
Two-circuit signalling
Send a position signal to two controllers or provide a redundant contact.
Polarity selection
Switch a DC circuit between two paths at a defined position.
Safety and monitoring
Use one pole for control and the other for a monitoring input, subject to the safety design.
Industrial limits
Detect end travel while changing a secondary circuit.
Equipment interlocks
Change two circuits when a guard, door or lever reaches a position.
How to choose a DPDT limit switch
- Contact form: confirm DPDT and the terminal arrangement.
- رتبهبندی: voltage, current, AC/DC and load type; check inrush.
- Actuator: plunger, lever, roller or custom; match the cam and travel.
- Mounting: body size, holes and adjustment range.
- Terminals: screw, quick-connect, PCB or wire harness.
- Environment: IP rating, temperature and contamination.
- Life and approvals: mechanical/electrical cycles and required certifications.
ZING EAR offers a DPDT micro limit switch positioned as an alternative to the Crouzet 83133169, plus the DPDT momentary micro switch و G21 DPDT limit switch.
Related limit switch guides
For position accuracy and repeatability, read the precision limit switch guide. For the full range, see the limit switch overview و types of micro switches.
DPDT limit switch FAQ
What does DPDT mean on a limit switch?
Double-pole, double-throw: two independent changeover circuits operated by one actuator. Each pole has a common contact, a normally open contact and a normally closed contact.
How many terminals does a DPDT switch have?
A typical DPDT switch has six terminals: two commons and four selectable contacts. The exact layout depends on the manufacturer.
Can a DPDT switch reverse a motor?
It can change polarity or control paths, but the switch rating and motor circuit must be designed correctly. For larger motors, use a relay or contactor and follow the controller diagram.
What is the difference between DPDT and SPDT?
SPDT has one changeover circuit; DPDT has two independent changeover circuits operated together.
How do I identify the common terminals?
Use the datasheet and a multimeter. The common terminal changes continuity from NC to NO when the actuator is operated.
Can ZING EAR customize a DPDT limit switch?
ZING EAR can review custom actuators, terminals, wiring and ratings for OEM projects.
Need a DPDT limit switch?
Send your circuit diagram, load, actuator and mounting requirements. ZING EAR can recommend a standard or custom DPDT switch.