Home / Limit Switch / DPDT Limit Switch

Changeover Control

DPDT Limit Switch: Contacts, Wiring & Selection Guide

A DPDT limit switch contains two independent changeover circuits operated by one actuator. This guide explains the contacts, wiring options, applications and how to choose a DPDT micro limit switch.

What is a DPDT limit switch?

DPDT means double-pole, double-throw. The switch has two independent poles, and each pole has a common contact that changes between a normally closed (NC) and normally open (NO) contact. One actuator operates both poles at the same time.

A DPDT limit switch is useful when one mechanical position must change two separate circuits, reverse a motor, select between two signals, or provide a redundant contact set. It is different from an SPDT switch, which has only one changeover circuit.

DPDT contact map

Terminal group At rest When actuated
COM 1 → NC 1 Closed Open
COM 1 → NO 1 Open Closed
COM 2 → NC 2 Closed Open
COM 2 → NO 2 Open Closed

Terminal markings vary by manufacturer. Always identify the two common terminals and their corresponding NO/NC contacts from the datasheet before wiring. Do not assume that the terminals are arranged in a particular order.

DPDT vs SPDT

SPDT

One common contact changes between one NO and one NC contact. Three terminals are typical. Good for a single changeover signal.

DPDT

Two independent changeover circuits. Six terminals are typical. Good for reversing, dual signals or isolated circuits.

DPST

Two independent on/off contacts, without changeover. Four terminals are typical.

For contact-state basics, see NO vs NC micro switches.

DPDT limit switch wiring

A common use is motor reversing. The two poles can swap the polarity or phase connections while the other contacts provide a signal or interlock. The exact wiring depends on the motor, controller and safety requirements.

  1. Identify both common terminals and their NO/NC contacts.
  2. Draw the circuit in the rest and actuated states before connecting power.
  3. Confirm that the switch rating covers the motor or load, including inrush current.
  4. Use a relay or contactor if the motor current exceeds the switch rating.
  5. Provide strain relief and protect terminals from accidental contact.
  6. Test the circuit with the actuator in both positions and verify the expected state change.
Motor reversing and line-voltage wiring can be dangerous. Use a qualified electrician and follow the motor controller’s wiring diagram. A micro switch should not be used beyond its published rating.

For terminal testing and COM/NO/NC identification, see the micro switch wiring guide.

Typical applications

Motor reversing

Change the polarity or control direction at a mechanical end position.

Two-circuit signalling

Send a position signal to two controllers or provide a redundant contact.

Polarity selection

Switch a DC circuit between two paths at a defined position.

Safety and monitoring

Use one pole for control and the other for a monitoring input, subject to the safety design.

Industrial limits

Detect end travel while changing a secondary circuit.

Equipment interlocks

Change two circuits when a guard, door or lever reaches a position.

How to choose a DPDT limit switch

  • Contact form: confirm DPDT and the terminal arrangement.
  • Rating: voltage, current, AC/DC and load type; check inrush.
  • Actuator: plunger, lever, roller or custom; match the cam and travel.
  • Mounting: body size, holes and adjustment range.
  • Terminals: screw, quick-connect, PCB or wire harness.
  • Environment: IP rating, temperature and contamination.
  • Life and approvals: mechanical/electrical cycles and required certifications.

ZING EAR offers a DPDT micro limit switch positioned as an alternative to the Crouzet 83133169, plus the DPDT momentary micro switch and G21 DPDT limit switch.

Related limit switch guides

For position accuracy and repeatability, read the precision limit switch guide. For the full range, see the limit switch overview and types of micro switches.

DPDT limit switch FAQ

What does DPDT mean on a limit switch?

Double-pole, double-throw: two independent changeover circuits operated by one actuator. Each pole has a common contact, a normally open contact and a normally closed contact.

How many terminals does a DPDT switch have?

A typical DPDT switch has six terminals: two commons and four selectable contacts. The exact layout depends on the manufacturer.

Can a DPDT switch reverse a motor?

It can change polarity or control paths, but the switch rating and motor circuit must be designed correctly. For larger motors, use a relay or contactor and follow the controller diagram.

What is the difference between DPDT and SPDT?

SPDT has one changeover circuit; DPDT has two independent changeover circuits operated together.

How do I identify the common terminals?

Use the datasheet and a multimeter. The common terminal changes continuity from NC to NO when the actuator is operated.

Can ZING EAR customize a DPDT limit switch?

ZING EAR can review custom actuators, terminals, wiring and ratings for OEM projects.

Need a DPDT limit switch?

Send your circuit diagram, load, actuator and mounting requirements. ZING EAR can recommend a standard or custom DPDT switch.

Request a sample